Macnaught MX Oval Gear Flow Meters are Industrial Grade Positive Displacement Flow Meter devices. Our MX Meters provide true volumetric measurement of liquid thru the meter – not of scale, but actual flow measurement.
MX Meter bodies are machined of solid billet, our Rotor shafts are hardened alloy and our Rotor design is unmatched for accuracy and reliability. Our MX PD Meters are for clean fluids, only – no gases or solids-laden liquids.
ALL MX METERS PROVIDE A STANDARD .5% ACCURACY with .03% Repeatability of Flow
Receive an Immediate Flow Meter Proposal or Call our Meter Hotline - 02 9556 5404
Fluid Categories Well Suited for MX Oval Gear Flow Meters
Fuels • Oils • Solvents • DEF/ADBLUE • Greases • Lubricants • Fuel Additives • Glycols Polyols • Isocyanates • Asphalt Emulsions • Sealers • Epoxies • Adhesives • DI Water General Water • Acids • Bases • Inks • Chemical Additives • All Clean Process Fluids
> Rail Car Fluid Flow Measurement
> Agriculture Chemical Flow Meter
> Marine Vessel Fuel Measurement
Applications Well Suited for Macnaught Oval Gear Flow Meters
Bio Diesel Blending & Production | Agriculture Chemical Blending & Dispensing |
Diesel Fuel Additive Blending | Ink Blending |
Fuel Measurement – Basic | Solvent Manufacturing, Blending, Dispensing |
Fuel Measurement – Advanced | Paint & Coating Manufacturing |
Ethanol Blends | Glycols Process Measurement |
Heating Oil Measurement | Sealants & Adhesive Manufacturing |
Boiler Fuel Measurement | Epoxy / Glue Production |
Bunker & Vessel Fuel Measurement | Polymer Production & Measurement |
Lubricant Blending & Dispensing | High Viscosity Fluid Measurement |
Hydraulic Fluid Measurement | DI and General Water Loop Measurement |
Test Stands | Additive Injection & Blending |
Polyurethane Foam Ratio Blending | Acids & Bases Measurement |
The measuring element of an oval gear meter consists of two high-precision splined oval-shaped gears (Rotors).
The gears are driven by the flow of the media and “mesh” together. In the presence of flow, exact known defined volumes of fluid are swept through the meter per each rotor rotation.
As flow increases, so does the rotational speed of the Rotors.
The number of revolutions is a precise highly accurate measure of the fluid that has passed through the meter. Regardless of viscosity, pressure, or temperature.
Each “active” Rotor rotation creates a pulse and is detected by a sensor. Each meter is individually calibrated per ISO 17025 standards to .5% accuracy
Model |
Size |
Flow Range |
Max Pressure |
Max Temp PPS Rotors |
Max Temp Peek /SS Rotors *Remote display only |
MX06 | ¼” | .5-100 LPH | 1,000 PSI | 80C | 120C SS Only |
MX09 | ¼” | .5-16.5 LPM | 1,000 PSI | 80C | 120C SS Only |
MX12 | ½” | 2-45 LPM | 2,000 PSI | 80C | 120C SS Only |
MX19 | ¾” | 3-80 LPM | 2,000 PSI | 80C | 120C SS or PEEK |
MX25 | 1” | 6-160 LPM | 2,000 PSI | 80C | 120C SS or PEEK |
MX40 | 1.5” | 10-350 LPM | 1,500 PSI | 80C | 120C SS or PEEK |
MX50 | 2” | 15-580 LPM | 1,200 PSI | 80C | 120C SS or PEEK |
MX75 | 3” | 20-1200 LPM | 175 PSI | 120C | 120C AL Only |
MX100 | 4” | 120-2500 LPM | 175 PSI | 120C | 120C AL Only |
Notes: Contact Macnaught Canada for a Detailed Applications Review and quick response Meter Proposal
Call our Meter Hotline 02 9556 5404 or use the RFQ Form Link Below
Materials Of Construction ¼” thru 2”. All Bodies are Machined from Solid Billet Block. Standard connections are FNPT, numerous connections options available. Standard Pulser is 1 Reed x 1 Hall with 1 Meter of Flying Lead Cable. Numerous Pulser Options are available. Numerous Display Options are available. All Integral Displays are limited to 176F
F Series – commonly used for all Fuels, Oils, Greases, Lubricants, all other clean process fluids to 80C
F = FNPT Connections / Anodized Aluminum body / PPS Rotors / Viton Body Seal
S Series – commonly used for Fuels, Oils, some Solvents, all other clean process fluids up to 120C
S = FNPT Connections / Anodized Aluminum Body / SS or PEEK Rotors / FEP Body Seal
P Series – commonly used for all above, most Solvents, all other clean process fluids up to 120C
P = FNPT Connections / 316SS Body / PPS or PEEK or SS Rotors / FEP Body Seal
150C Maximum High Temp Sensor is available for all sizes. Contact Macnaught for Details
Higher Pressure Ranges are available in ¼” ( 8000 PSI ) and ½” ( 3,000 PSI ) M Series Models – contact Macnaught for Details
PPS Body and Rotor ( CR Series ) all plastic Meters available in both ¼” and 1” sizes - contact Macnaught for Details
MX75 ( 3” ) and MX100 ( 4” ) Meters are cast Aluminum only with Aluminum Rotors only. Viton or FEP Body Seal. Limited pressure range of 175 PSI
MX Meter Instruction Manual > Download PDF
Review this Manual for Installation Guidelines, Pulse Options, Wiring Instructions, Meter and Meter Part Numbering.
PR Integral or Remote Mount Display with Rate & Total Only – no outputs > Download PDF
Our PR Display is battery-powered ( 3 year life, common replacement type ) and offers Rate and total only. Total is resettable and non-resettable.
Integral Mount is limited to 80C maximum temperature.
PRA Integral or Remote Mount Display with Rate and Total with 4-20mA, Pulse and Flow Alarm ( Hi-Low ) outputs > Download PDF
Analog output requires loop-power.
Pulse output / alarms require 9-30 VDC.
Integral Mount is limited to 80C maximum temperature.
B-Smart Remote Display accepts all Macnaught Pulse Outputs > Data Sheet Download PDF
B-Smart Remote Display > Instruction Manual PDF
No external power required for Rate & Total Only.
Analog / Pulse Output. Analog loop-powered pulse requires voltage.
Numerous engineering value options including lb, kg, ton
PRM Integral of Remote Mount Display 4-20mA only – no rate or total values > Download PDF
External loop power required.
Integral Mount is limited to 80C maximum temperature.
Note: Additional specific use displays are available.
Pulser Output Options > Download PDF
Includes wiring and specifications for Reed x Reed, Hall x Hall, High Resolution ( Double Pulse ), Industrial Pulse Cap and DIN Pulse Module
Meter Hotline at 02 9556 5404
Stay Connected
Subscribe to get Notified of Sales, Specials + Exclusive
Copyright © 2024 Macnaught Pty Ltd, All rights reserved.
Item | Price | Qty | Total | |
---|---|---|---|---|
Subtotal |
$0.00 |
|||
Shipping | ||||
Total |
Macnaught MX Oval Gear Flow Meters are Industrial Grade Positive Displacement Flow Meter devices. Our MX Meters provide true volumetric measurement of liquid thru the meter – not of scale, but actual flow measurement.
MX Meter bodies are machined of solid billet, our Rotor shafts are hardened alloy and our Rotor design is unmatched for accuracy and reliability. Our MX PD Meters are for clean fluids, only – no gases or solids-laden liquids.
ALL MX METERS PROVIDE A STANDARD .5% ACCURACY with .03% Repeatability of Flow
Receive an Immediate Flow Meter Proposal or Call our Meter Hotline - 02 9556 5404
Fluid Categories Well Suited for MX Oval Gear Flow Meters
Fuels • Oils • Solvents • DEF/ADBLUE • Greases • Lubricants • Fuel Additives • Glycols Polyols • Isocyanates • Asphalt Emulsions • Sealers • Epoxies • Adhesives • DI Water General Water • Acids • Bases • Inks • Chemical Additives • All Clean Process Fluids
> Rail Car Fluid Flow Measurement
> Agriculture Chemical Flow Meter
> Marine Vessel Fuel Measurement
Applications Well Suited for Macnaught Oval Gear Flow Meters
Bio Diesel Blending & Production | Agriculture Chemical Blending & Dispensing |
Diesel Fuel Additive Blending | Ink Blending |
Fuel Measurement – Basic | Solvent Manufacturing, Blending, Dispensing |
Fuel Measurement – Advanced | Paint & Coating Manufacturing |
Ethanol Blends | Glycols Process Measurement |
Heating Oil Measurement | Sealants & Adhesive Manufacturing |
Boiler Fuel Measurement | Epoxy / Glue Production |
Bunker & Vessel Fuel Measurement | Polymer Production & Measurement |
Lubricant Blending & Dispensing | High Viscosity Fluid Measurement |
Hydraulic Fluid Measurement | DI and General Water Loop Measurement |
Test Stands | Additive Injection & Blending |
Polyurethane Foam Ratio Blending | Acids & Bases Measurement |
The measuring element of an oval gear meter consists of two high-precision splined oval-shaped gears (Rotors).
The gears are driven by the flow of the media and “mesh” together. In the presence of flow, exact known defined volumes of fluid are swept through the meter per each rotor rotation.
As flow increases, so does the rotational speed of the Rotors.
The number of revolutions is a precise highly accurate measure of the fluid that has passed through the meter. Regardless of viscosity, pressure, or temperature.
Each “active” Rotor rotation creates a pulse and is detected by a sensor. Each meter is individually calibrated per ISO 17025 standards to .5% accuracy
Model |
Size |
Flow Range |
Max Pressure |
Max Temp PPS Rotors |
Max Temp Peek /SS Rotors *Remote display only |
MX06 | ¼” | .5-100 LPH | 1,000 PSI | 80C | 120C SS Only |
MX09 | ¼” | .5-16.5 LPM | 1,000 PSI | 80C | 120C SS Only |
MX12 | ½” | 2-45 LPM | 2,000 PSI | 80C | 120C SS Only |
MX19 | ¾” | 3-80 LPM | 2,000 PSI | 80C | 120C SS or PEEK |
MX25 | 1” | 6-160 LPM | 2,000 PSI | 80C | 120C SS or PEEK |
MX40 | 1.5” | 10-350 LPM | 1,500 PSI | 80C | 120C SS or PEEK |
MX50 | 2” | 15-580 LPM | 1,200 PSI | 80C | 120C SS or PEEK |
MX75 | 3” | 20-1200 LPM | 175 PSI | 120C | 120C AL Only |
MX100 | 4” | 120-2500 LPM | 175 PSI | 120C | 120C AL Only |
Notes: Contact Macnaught Canada for a Detailed Applications Review and quick response Meter Proposal
Call our Meter Hotline 02 9556 5404 or use the RFQ Form Link Below
Materials Of Construction ¼” thru 2”. All Bodies are Machined from Solid Billet Block. Standard connections are FNPT, numerous connections options available. Standard Pulser is 1 Reed x 1 Hall with 1 Meter of Flying Lead Cable. Numerous Pulser Options are available. Numerous Display Options are available. All Integral Displays are limited to 176F
F Series – commonly used for all Fuels, Oils, Greases, Lubricants, all other clean process fluids to 80C
F = FNPT Connections / Anodized Aluminum body / PPS Rotors / Viton Body Seal
S Series – commonly used for Fuels, Oils, some Solvents, all other clean process fluids up to 120C
S = FNPT Connections / Anodized Aluminum Body / SS or PEEK Rotors / FEP Body Seal
P Series – commonly used for all above, most Solvents, all other clean process fluids up to 120C
P = FNPT Connections / 316SS Body / PPS or PEEK or SS Rotors / FEP Body Seal
150C Maximum High Temp Sensor is available for all sizes. Contact Macnaught for Details
Higher Pressure Ranges are available in ¼” ( 8000 PSI ) and ½” ( 3,000 PSI ) M Series Models – contact Macnaught for Details
PPS Body and Rotor ( CR Series ) all plastic Meters available in both ¼” and 1” sizes - contact Macnaught for Details
MX75 ( 3” ) and MX100 ( 4” ) Meters are cast Aluminum only with Aluminum Rotors only. Viton or FEP Body Seal. Limited pressure range of 175 PSI
MX Meter Instruction Manual > Download PDF
Review this Manual for Installation Guidelines, Pulse Options, Wiring Instructions, Meter and Meter Part Numbering.
PR Integral or Remote Mount Display with Rate & Total Only – no outputs > Download PDF
Our PR Display is battery-powered ( 3 year life, common replacement type ) and offers Rate and total only. Total is resettable and non-resettable.
Integral Mount is limited to 80C maximum temperature.
PRA Integral or Remote Mount Display with Rate and Total with 4-20mA, Pulse and Flow Alarm ( Hi-Low ) outputs > Download PDF
Analog output requires loop-power.
Pulse output / alarms require 9-30 VDC.
Integral Mount is limited to 80C maximum temperature.
B-Smart Remote Display accepts all Macnaught Pulse Outputs > Data Sheet Download PDF
B-Smart Remote Display > Instruction Manual PDF
No external power required for Rate & Total Only.
Analog / Pulse Output. Analog loop-powered pulse requires voltage.
Numerous engineering value options including lb, kg, ton
PRM Integral of Remote Mount Display 4-20mA only – no rate or total values > Download PDF
External loop power required.
Integral Mount is limited to 80C maximum temperature.
Note: Additional specific use displays are available.
Pulser Output Options > Download PDF
Includes wiring and specifications for Reed x Reed, Hall x Hall, High Resolution ( Double Pulse ), Industrial Pulse Cap and DIN Pulse Module
Meter Hotline at 02 9556 5404